PortalRankings.com
 

Websites targeting keyword air + steam mixture

3 websites are using keyword air + steam mixture in their content.

 
Total results: 3
Domains on this page: 3
 

Different keywords:

 

Results:

Retort Sterilizers, Food Equipment, Pharma Equipment, Hospital Equipment, Mumbai, India
http://portalrankings.com/info/retortsterilizers.com
Manufacturer Of Retort Sterilizers, Food Equipment, Pharma Equipment, Hospital Equipment, Pharmaceutical Equipment, Mumbai, India
  • Updated On (Date): 2017-Aug-18
  • Expiration time: 2018-Mar-21
  • Website Registered On (Date): 2014-Mar-21
Home
http://portalrankings.com/info/powerplantinterview.com
BOILER QUESTIONS AND ANSWERS Q. What is boiler. A. According to Indian Boiler Act 1923, a boiler is a closed pressure vessel / steam generating unit with minimum capacity of 22.70 liters, including all mountings and accessories. Q. What is circulation ratio of a boiler. A. It is the ratio of the quantity of water-steam mixture flowing through the circuit to the quantity of steam produced in the circuit , The circulation ratio of once through / super critical boiler is one because all water Is converted to steam. The circulation ratios of 1. Natural circulation industrial boiler - 10 to 15 2. Natural circulation utility boiler - 7 to 9 3. Assisted circulation boilers - 2 to 4 4. Forced circulation / once through boiler - 1 Q What are the boiler mountings. A. The boiler mountings are used for safe and efficient operation of boiler, these are placed in out side of the boiler. 1. Safety valve. 2.pressure gauge. 3.Water level gauge glass.. Pressure gauge. 4. Start-up vent. 5.Air vent. 5.Manhole. Q. What are boiler accessories. A. These are the integral part of boiler which help to run the boiler most efficiently These are, 1. Super heater. 2. Economizer. 3.Air pre- heater. 4.ID and FD fans. 5. Ash handling system. 6.Dosing system. 7. Soot blower. 8.De super heating system. Q. What is turn down ratio of boiler. A. It is the operating range of boiler from maximum capacity to minimum capacity in which the boiler can run efficiently without any external fuel support . The higher turn down ratio greater the efficiency of boiler. For example if the boiler is designed 80mw and can operate up to 20mw without any external fuel support and any variations of parameter then the turn down ratio is 80/20=4. Q. What is boiler efficiency. A. It is the ratio of heat output to heat input of the boiler. Boiler efficiency= Heat output / hea
  • Updated On (Date): 2017-May-04
  • Expiration time: 2018-May-06
  • Website Registered On (Date): 2015-May-06
Steelco S.p.A. - Washer disinfectors and Sterilizers - Home
http://portalrankings.com/info/steelcospa.com
Steelco is a leading infection control solution provider, supplying the healthcare, laboratory research and pharma sectors. Active in over 100 countries, Steelco has equipped numerous world renown hospitals and counts among its customers household names in the laboratory, pharmaceutical and industrial sectors.
  • Google Analytics code: 10588365-1
  • Updated On (Date): 2017-Jan-09
  • Expiration time: 2018-Jan-29
  • Website Registered On (Date): 1999-Jan-29
2024-05-08 18:33:57 || 0.0060